Filter Pack Porosity
When should I enter a porosity for the gravel pack of the well? | |
AQTESOLV uses the porosity of the gravel pack to correct the casing radius of the well when the static water table position occurs within the well screen (i.e., a partially submerged screen).
For confined aquifers, always enter a porosity of 0.0. For unconfined aquifers, enter the gravel pack porosity only when the static water table position occurs within the well screen; otherwise enter a porosity of 0.0. In v3.0 and higher, check Apply correction for partially submerged screen if you want AQTESOLV to correct the casing radius. In older versions, the program will apply the correction whenever the porosity value is greater than 0.0. |